How to Clean and Care for a Unifrost CRS90G Without Damaging It
(0) How to Clean and Care for a Unifrost CRS90G Without Damaging It
Manual-based CRS90G cleaning guidance covering power isolation, prohibited cleaning methods, door-seal care, food storage and condenser work.
Why Are Blue Plasters Used in Catering? A Comprehensive Guide
(0) Why Are Blue Plasters Used in Catering? A Comprehensive Guide
The goal of this blog is to educate readers on the importance of using blue plasters in catering environments, explaining their purpose, legal requirements, and benefits for food safety.
Unifrost HVR21B Display Fridge Cleaning: Safe Care for Seals, Surfaces and Vents
Unifrost HVR21B Display Fridge Cleaning: Safe Care for Seals, Surfaces and Vents
Disconnect the HVR21B from the power outlet before cleaning. Use a soft cloth with lukewarm water, adding only diluted neutral kitchen detergent for stubborn dirt, then remove residue and dry the surfaces. Avoid water spray, abrasive cleaners and chemical mixtures. Clean seals promptly, treat ventilation openings gently and leave damage or internal work to an authorised service centre.
Banks WB12 Water Boiler Care: Start-Up, Cleaning and Safe Leak Checks
Banks WB12 Water Boiler Care: Start-Up, Cleaning and Safe Leak Checks
The WB12 is for trained operators. Start by connecting and turning on the water, then visually check accessible pipes and connections for leaks before connecting power. Keep the steam release outlet unobstructed, never open the drain while the unit is in use or hot, and leave overload resets and internal faults to qualified service. Disconnect power for cleaning, use a wet towel, and avoid hosing, caustic chemicals and abrasives.
Chefsrange AD10 Mixer Attachments and Speeds for Dough, Beating and Whipping
Chefsrange AD10 Mixer Attachments and Speeds for Dough, Beating and Whipping
A source-locked AD10 guide to selecting the dough arm, beater or wire whip, observing the stated capacity and changing attachments with the mixer stopped.
Italforni EGA-1 Burner Will Not Stay Lit? Operator Reset Limits and When to Call Service
Italforni EGA-1 Burner Will Not Stay Lit? Operator Reset Limits and When to Call Service
For a trained operator, the EGA-1 permits a tightly limited burner-reset sequence: press the external red burner reset button once. Only if the red warning light remains on may the button be pressed one further time after “a few minutes”. If the burner still does not ignite, stop resetting and contact the technical service centre. If it ignites but then repeatedly goes out, do not cycle the reset: the manual provides no separate operator repair procedure for recurring shutdown, so refer it to technical service. [EGA1-20-01, EGA1-21-02, EGA1-21-03, EGA1-21-04, EGA1-19-01]
How to Change the Temperature on a TEFCOLD GUC70 Fridge Controller
How to Change the Temperature on a TEFCOLD GUC70 Fridge Controller
Hold SET for three seconds until the °C symbol flickers, adjust the displayed value with the arrow buttons, and release the buttons to set the new temperature. This guide covers only the normal operator controls documented for the TEFCOLD GUC70.
How to Edit and Save a Cooking Programme in the Lincat CiBO Recipe Manager
How to Edit and Save a Cooking Programme in the Lincat CiBO Recipe Manager
A source-locked guide to editing and saving an existing recipe in the Lincat CiBO Recipe Manager, with clear limits around CiBO+ and food-safety validation.
How to Clean and Sanitise a Blizzard BIM40 Ice Maker
How to Clean and Sanitise a Blizzard BIM40 Ice Maker
A source-locked cleaning guide that separates manual cleaning from the powered automatic cycle and escalates ambiguous internal maintenance to qualified personnel.
Combisteel 7013.2570 Not Cooling Properly? Safe Checks Before Calling an Engineer
Combisteel 7013.2570 Not Cooling Properly? Safe Checks Before Calling an Engineer
Check the Combisteel 7013.2570’s external power supply, installation clearance, location, door closure and operator temperature setting before escalating. Do not open the appliance or attempt electrical, refrigerant or sealed-system diagnosis.